Jackery Explorer 1500 v2
Enough24.1h
of your routine
2.0 h
with everything running nonstop
1,536 Wh × 0.85 = 1,306 Wh usable, your routine uses 1,300 Wh a day
- Capacity
- 1,536 Wh
- Weight
- 32 lb (14.5 kg)
- Price
- $949 list price, October 2026
Of the 54 power stations in the Enough Watts data set, 30 are enough for one full day without a recharge, 13 run it but not long enough, and 11 cannot power it. The closest fit is the Jackery Explorer 1500 v2 (1,536 Wh), with 24.1 h of this routine.
Updated
650W
Running, all at once
1,300W
Starting watts needed
1,300Wh
Energy a day
30 of 54
Enough for 24 h
| Appliance | How many | Running | Energy a day |
|---|---|---|---|
| Sump pump (1/3 HP) | 1 | 650 W | 650 W × 2 h = 1,300 Wh |
The 54 power stations in the data set, ranked smallest capacity first (the closest fit), then lower price, then lighter. Whether a link can earn us money never changes the order.
Enough Watts may earn a commission when you buy through links on this page. It never changes the math or the ranking.
24.1h
of your routine
2.0 h
with everything running nonstop
1,536 Wh × 0.85 = 1,306 Wh usable, your routine uses 1,300 Wh a day
24.1h
of your routine
2.0 h
with everything running nonstop
1,536 Wh × 0.85 = 1,306 Wh usable, your routine uses 1,300 Wh a day
30.1h
of your routine
2.5 h
with everything running nonstop
1,920 Wh × 0.85 = 1,632 Wh usable, your routine uses 1,300 Wh a day
32.0h
of your routine
2.7 h
with everything running nonstop
2,042 Wh × 0.85 = 1,736 Wh usable, your routine uses 1,300 Wh a day
32.1h
of your routine
2.7 h
with everything running nonstop
2,048 Wh × 0.85 = 1,741 Wh usable, your routine uses 1,300 Wh a day
32.1h
of your routine
2.7 h
with everything running nonstop
2,048 Wh × 0.85 = 1,741 Wh usable, your routine uses 1,300 Wh a day
| Power station | Capacity | Runtime of this routine | Everything nonstop |
|---|---|---|---|
| Pecron E2400LFP | 2,048 Wh | 32.1 h | 2.7 h |
| Anker SOLIX C2000 Gen 2 | 2,048 Wh | 32.1 h | 2.7 h |
| EcoFlow DELTA 3 Max Plus | 2,048 Wh | 32.1 h | 2.7 h |
| OUPES Mega 2 Pro | 2,048 Wh | 32.1 h | 2.7 h |
| DJI Power 2000 | 2,048 Wh | 32.1 h | 2.7 h |
| BLUETTI Elite 200 V2 | 2,074 Wh | 32.5 h | 2.7 h |
| Anker SOLIX F2600 | 2,560 Wh | 40.2 h | 3.3 h |
| BLUETTI Apex 300 | 2,765 Wh | 43.4 h | 3.6 h |
| BLUETTI Elite 300 | 3,014 Wh | 47.3 h | 3.9 h |
| EcoFlow DELTA 3 Ultra | 3,072 Wh | 2.0 days | 4.0 h |
| Anker SOLIX F3000 | 3,072 Wh | 2.0 days | 4.0 h |
| EcoFlow DELTA 3 Ultra Plus | 3,072 Wh | 2.0 days | 4.0 h |
| Pecron E3600LFP | 3,072 Wh | 2.0 days | 4.0 h |
| ALLPOWERS R3500 | 3,168 Wh | 2.1 days | 4.1 h |
| ALLPOWERS R4000 | 3,456 Wh | 2.3 days | 4.5 h |
| BLUETTI Elite 400 | 3,840 Wh | 2.5 days | 5.0 h |
| Anker SOLIX F3800 | 3,840 Wh | 2.5 days | 5.0 h |
| Anker SOLIX F3800 Plus | 3,840 Wh | 2.5 days | 5.0 h |
| Goal Zero Yeti PRO 4000 | 3,994 Wh | 2.6 days | 5.2 h |
| EcoFlow DELTA Pro 3 | 4,096 Wh | 2.7 days | 5.4 h |
| OUPES Guardian 6000 V2 | 4,608 Wh | 3.0 days | 6.0 h |
| Jackery Explorer 5000 Plus | 5,040 Wh | 3.3 days | 6.6 h |
| EcoFlow DELTA Pro Ultra | 6,144 Wh | 4.0 days | 8.0 h |
| EcoFlow DELTA Pro Ultra X | 12,288 Wh | 8.0 days | 16.1 h |
They pass the output, surge and voltage checks but run out before the goal. Longest runtime first.
| Power station | Capacity | Runtime of this routine | Everything nonstop |
|---|---|---|---|
| Goal Zero Yeti 1500 | 1,505 Wh | 23.6 h | 2.0 h |
| Jackery Explorer 1000 Plus | 1,265 Wh | 19.8 h | 1.7 h |
| BLUETTI AC180 | 1,152 Wh | 18.1 h | 1.5 h |
| ALLPOWERS R1500 | 1,152 Wh | 18.1 h | 1.5 h |
| Jackery Explorer 1000 v2 | 1,070 Wh | 16.8 h | 1.4 h |
| Anker SOLIX C1000 | 1,056 Wh | 16.6 h | 1.4 h |
| BLUETTI Elite 100 V2 | 1,024 Wh | 16.1 h | 1.3 h |
| EcoFlow DELTA 3 Classic | 1,024 Wh | 16.1 h | 1.3 h |
| Anker SOLIX C1000 Gen 2 | 1,024 Wh | 16.1 h | 1.3 h |
| EcoFlow DELTA 3 | 1,024 Wh | 16.1 h | 1.3 h |
| EcoFlow DELTA 3 Plus | 1,024 Wh | 16.1 h | 1.3 h |
| Pecron E1000LFP | 1,024 Wh | 16.1 h | 1.3 h |
| DJI Power 1000 | 1,024 Wh | 16.1 h | 1.3 h |
A 1/3 HP sump pump on a power station uses about 1,300 Wh a day at 2 hours of motor time, so a full day takes about 1,529 Wh of rated capacity at 85%, and 30 of the 54 stations are enough for it. If a storm cuts the power while it fills the pit, the pump stops when it is needed most. The motor needs about 1,300 W for a moment at each start, 2 times its 650 W running figure, and 11 of the 54 stations fail on that start alone.
Then the battery. No official source publishes how long a sump pump runs in a day, because that depends on the water coming in. This page counts 2 hours of motor run time a day and assumes the motor runs flat out whenever it is on. On a wet day the pump can run much longer; enter the hours you see in the calculator.
Check how your pump connects before you count on this. A pump with a plug can go straight into the station. A hard wired pump needs an electrician, and a station must never be connected to house wiring without a transfer switch or inlet.
A larger 1/2 HP pump raises both the running and the starting watts, and the question below works it out.
Read more: Watts vs watt hours, explained, Why you get less than the rated capacity and Starting watts explained.